When considering seismic loads for LNG tanks and their containment systems, several factors should be taken into account. One of the most important factors is regional seismic and geological data. This data can provide insight into the likelihood and potential magnitude of earthquakes that could occur in the area.

Another key factor to consider is the expected recurrence rates and maximum earthquake magnitudes for known faults and seismic zones in the region. By analyzing seismic data from past earthquakes, engineers can estimate the probability of future earthquakes and their potential impact on structures such as LNG tanks.

The location of the site and its relationship to potential hazards is also important. For example, if the site is located near a fault line or in an area with a high likelihood of earthquakes, additional precautions may need to be taken to ensure that the LNG tank and its containment system are able to withstand seismic loads.

In addition to these factors, it is important to consider the characteristics of the subsurface conditions in the area. Soil type, groundwater levels, and other factors can impact the ability of the LNG tank and its containment system to withstand seismic loads.

Finally, it is important to consider the potential for aftershocks and other post-seismic events to impact the LNG tank and its containment system. By taking all of these factors into account, designers and engineers can ensure that LNG tanks and their containment systems are able to withstand seismic loads and protect nearby communities from potential hazards.